Interface
|
N Male |
|
Body Style
|
Straight |
|
Brand
|
HELIAX® |
|
Mounting Angle
|
Straight |
|
|
Connector Impedance
|
50 ohm |
|
Operating Frequency Band
|
0 – 12000 MHz |
|
Cable Impedance
|
50 ohm |
|
3rd Order IMD, typical
|
-120 dBm @ 910 MHz |
|
3rd Order IMD Test Method
|
Two +43 dBm carriers |
|
RF Operating Voltage, maximum (vrms)
|
707.00 V |
|
dc Test Voltage
|
2000 V |
|
Outer Contact Resistance, maximum
|
0.30 mOhm |
|
Inner Contact Resistance, maximum
|
2.00 mOhm |
|
Insulation Resistance, minimum
|
5000 MOhm |
|
Average Power
|
0.6 kW @ 900 MHz |
|
Peak Power, maximum
|
10.00 kW |
Insertion Loss, typical
|
0.05 dB |
|
Shielding Effectiveness
|
-110 dB |
|
Click on image below to enlarge.
|
|
|
|
|
Outer Contact Attachment Method
|
Crush-flare |
|
Inner Contact Attachment Method
|
Captivated |
|
Outer Contact Plating
|
Unplated |
|
Inner Contact Plating
|
Silver |
|
Attachment Durability
|
25 cycles |
|
Interface Durability
|
500 cycles |
|
Interface Durability Method
|
IEC 61169-16:9.5 |
|
Connector Retention Tensile Force
|
890 N | 200 lbf |
|
Connector Retention Torque
|
5.42 N-m | 48.00 in lb |
|
Insertion Force
|
66.72 N | 15.00 lbf |
|
Insertion Force Method
|
MIL-C-39012C-3.12, 4.6.9 |
|
Pressurizable
|
No |
|
Coupling Nut Proof Torque
|
4.52 N-m | 40.00 in lb |
|
Coupling Nut Retention Force
|
444.82 N | 100.00 lbf |
|
Coupling Nut Retention Force Method
|
MIL-C-39012C-3.25, 4.6.22 |
|
|
Nominal Size
|
1/2 in |
|
Diameter
|
23.62 mm | 0.93 in |
|
Length
|
53.98 mm | 2.13 in |
|
Weight
|
90.72 g | 0.20 lb |
|
|
Operating Temperature
|
-55 °C to +85 °C (-67 °F to +185 °F) |
|
Storage Temperature
|
-55 °C to +85 °C (-67 °F to +185 °F) |
Immersion Depth
|
1 m |
|
Immersion Test Mating
|
Mated |
|
Immersion Test Method
|
IEC 60529:2001, IP68 |
|
Water Jetting Test Mating
|
Mated |
|
Water Jetting Test Method
|
IEC 60529:2001, IP66 |
|
Moisture Resistance Test Method
|
MIL-STD-202F, Method 106F |
|
Mechanical Shock Test Method
|
MIL-STD-202F, Method 213B, Test Condition C |
|
Thermal Shock Test Method
|
MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C |
|
Vibration Test Method
|
MIL-STD-202F, Method 204D, Test Condition B |
|
Corrosion Test Method
|
MIL-STD-1344A, Method 1001.1, Test Condition A |
|
|
Attenuation, Ambient Temperature
|
20 °C | 68 °F |
|
Average Power, Ambient Temperature
|
40 °C | 104 °F |