Interface
|
N Male |
Body Style
|
Straight |
Brand
|
HELIAX® |
Mounting Angle
|
Straight |
|
Connector Impedance
|
50 ohm |
Operating Frequency Band
|
0 – 12000 MHz |
Cable Impedance
|
50 ohm |
3rd Order IMD, typical
|
-120 dBm @ 910 MHz |
3rd Order IMD Test Method
|
Two +43 dBm carriers |
RF Operating Voltage, maximum (vrms)
|
707.00 V |
dc Test Voltage
|
2000 V |
Outer Contact Resistance, maximum
|
0.30 mOhm |
Inner Contact Resistance, maximum
|
2.00 mOhm |
Insulation Resistance, minimum
|
5000 MOhm |
Average Power
|
0.6 kW @ 900 MHz |
Peak Power, maximum
|
10.00 kW |
Insertion Loss, typical
|
0.05 dB |
Shielding Effectiveness
|
-110 dB |
|
Click on image below to enlarge.
|
|
|
|
Outer Contact Attachment Method
|
Crush-flare |
Inner Contact Attachment Method
|
Captivated |
Outer Contact Plating
|
Unplated |
Inner Contact Plating
|
Silver |
Attachment Durability
|
25 cycles |
Interface Durability
|
500 cycles |
Interface Durability Method
|
IEC 61169-16:9.5 |
Connector Retention Tensile Force
|
890 N | 200 lbf |
Connector Retention Torque
|
5.42 N-m | 48.00 in lb |
Insertion Force
|
66.72 N | 15.00 lbf |
Insertion Force Method
|
MIL-C-39012C-3.12, 4.6.9 |
Pressurizable
|
No |
Coupling Nut Proof Torque
|
4.52 N-m | 40.00 in lb |
Coupling Nut Retention Force
|
444.82 N | 100.00 lbf |
Coupling Nut Retention Force Method
|
MIL-C-39012C-3.25, 4.6.22 |
|
Nominal Size
|
1/2 in |
Diameter
|
23.62 mm | 0.93 in |
Length
|
53.98 mm | 2.13 in |
Weight
|
90.72 g | 0.20 lb |
|
Operating Temperature
|
-55 °C to +85 °C (-67 °F to +185 °F) |
Storage Temperature
|
-55 °C to +85 °C (-67 °F to +185 °F) |
Immersion Depth
|
1 m |
Immersion Test Mating
|
Mated |
Immersion Test Method
|
IEC 60529:2001, IP68 |
Water Jetting Test Mating
|
Mated |
Water Jetting Test Method
|
IEC 60529:2001, IP66 |
Moisture Resistance Test Method
|
MIL-STD-202F, Method 106F |
Mechanical Shock Test Method
|
MIL-STD-202F, Method 213B, Test Condition C |
Thermal Shock Test Method
|
MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C |
Vibration Test Method
|
MIL-STD-202F, Method 204D, Test Condition B |
Corrosion Test Method
|
MIL-STD-1344A, Method 1001.1, Test Condition A |
|
Attenuation, Ambient Temperature
|
20 °C | 68 °F |
Average Power, Ambient Temperature
|
40 °C | 104 °F |